What three things are needed for a fire to start?

Answer: A source of ignition, a source of fuel, and oxygen

2

How can a fire start on site from something as small as a spark?

Answer: It only takes an ignition source, such as a small flame or electrical spark, together with air

3

Which of these is a hot work activity that can start a fire?

Answer: Welding or grinding

4

Which precautions does HSE list for hot work?

Answer: Clear combustible materials, have suitable extinguishers, and keep a careful watch throughout

5

On larger projects, what system can help manage the fire risk from hot work?

Answer: A permit to work system

6

Where should flammable materials such as LPG ideally be stored?

Answer: Outside the building under construction

7

Why does LPG need strict precautions when it is stored and used?

Answer: It has been involved in many serious fires and explosions, especially from leaks in confined areas

8

Why is good housekeeping important for fire safety on site?

Answer: Tidy sites have less rubbish and waste to act as fuel for a fire

9

Should bonfires be used to get rid of waste on site?

Answer: No — they should not normally be allowed on site

10

Can a worker sleep inside a building that is under construction?

Answer: No — no one should sleep in a building under construction or refurbishment

11

Who usually carries out the fire risk assessment for a construction site?

Answer: The responsible person — usually the main or principal contractor in control of the site

12

Where should escape routes on site lead to?

Answer: A safe place where people can assemble and be accounted for

13

What must be true of the fire warning on a construction site?

Answer: It must be audible above other noise and recognisable by everyone

14

Where should fire extinguishers be kept on a construction site?

Answer: At identified fire points around the site

15

Which type of extinguisher does HSE list for fires involving wood, paper and cloth?

Answer: Water

16

Which type of extinguisher does HSE list for electrical fires?

Answer: Carbon dioxide (CO2)

17

Which types of extinguisher does HSE list for flammable liquid fires?

Answer: Dry powder or foam

18

Who should be trained to use fire extinguishers on site?

Answer: Nominated people, so they know how to use them properly

19

What does CDM 2015 say about fire-fighting equipment and alarm systems on site?

Answer: They must be inspected, tested at suitable intervals and kept in good repair

20

What must happen before someone carries out work with a particular fire risk, such as hot work?

Answer: They must receive suitable instruction first

21

How should the site's smoking rules be handled?

Answer: Brought to the attention of all workers and visitors, and enforced

22

Who has legal duties to control fire risks on a construction project?

Answer: Clients, designers, principal designers and contractors

23

What does HSE say is the main purpose of fire extinguishers on a construction site?

Answer: To help people escape; trained people may tackle small, early fires

24

How does HSE say the amount of materials and waste kept on site should be managed to reduce fire risk?

Answer: Keep it to a minimum, stored in designated secure areas

25

Why does HSE say construction sites should be kept secure, especially at night and at weekends?

Answer: To help prevent fires on site

26

Can an old building be demolished by setting fire to it?

Answer: No — demolition by burning is not generally acceptable, as buildings contain materials that must not be burned

27

Which kind of site does HSE say may need a fixed, interconnected fire alarm system rather than relying on shouting?

Answer: High-risk or larger sites, such as timber-frame projects

28

Work is being done inside an occupied office building. What must the work not interfere with?

Answer: Existing escape routes, fire separation, alarms, dry risers or sprinklers

29

When should signs be provided for escape routes on site?

Answer: Where people are unfamiliar with the routes

30

Who does HSE list among the people at risk who must be considered in a site fire risk assessment?

Answer: Workers, contractors, visitors and vulnerable people

31

When should a site fire risk assessment be checked again?

Answer: Regularly, and whenever the site changes

32

Under CDM 2015, what must happen to the site's emergency arrangements once they are set up?

Answer: Everyone they cover must know about them, and they must be tested at suitable intervals

33

Which of these must emergency procedures on a construction site include?

Answer: Procedures for evacuating the site or any part of it

34

What does CDM 2015 say about emergency routes and exits, where needed?

Answer: They must be kept clear, marked with signs, and have emergency lighting where necessary

35

How must fire-fighting equipment that doesn't work automatically be placed on site?

Answer: Easily accessible, and marked with suitable signs

36

Regulation 29 of CDM 2015 requires steps to prevent injury from which risks?

Answer: Fire or explosion, flooding, and asphyxiating substances

37

What is fire-stopping?

Answer: A seal that closes gaps between building parts to restrict fire and smoke

38

What is a fire compartment in a building?

Answer: A part of the building built to stop fire spreading to or from other parts

39

You run a cable through a hole in a compartment wall. What must happen to the gap around it?

Answer: It must be sealed with suitable fire-stopping

40

Why does it matter if a hole for a service through a fire wall is not sealed?

Answer: Fire and smoke can spread through it into the next compartment

41

When a pipe passes through a fire-separating wall, how big should the opening be, if no tested sealing system is used?

Answer: As small as possible, with fire-stopping around the pipe

42

What does Approved Document B say a proprietary sealing system around a pipe must do?

Answer: Keep the fire resistance of the wall or floor

43

What is a cavity barrier?

Answer: Construction inside a hidden cavity that stops fire and smoke spreading through it

44

A fire door has a sign saying "Fire door keep shut". What does this mean?

Answer: Keep it closed when it is not being used

45

Why should you never wedge open a self-closing fire door?

Answer: It cannot close to stop fire and smoke spreading

46

Which device can legally hold a self-closing fire door open?

Answer: An automatic release linked to the fire alarm system

47

A fire door says "Automatic fire door keep clear". What does this tell you?

Answer: It is held open by a device that closes it in a fire, so keep the area clear

48

You need to cut a new hole through a compartment wall for your cables. What should you do first?

Answer: Get permission, and make sure it will be properly fire-stopped afterwards

49

What does the Building Safety Act 2022 call a building in England that is at least 18 metres high or has at least 7 storeys, with at least 2 homes?

Answer: A higher-risk building

50

What height makes a block of flats in England a higher-risk building under the Building Safety Act 2022?

Answer: At least 18 metres

51

Who is the building control authority for higher-risk buildings in England?

Answer: The Building Safety Regulator

52

Since January 2026, what kind of organisation is the Building Safety Regulator?

Answer: A standalone body, no longer part of HSE

53

Which disaster led to the Building Safety Act 2022 and the Building Safety Regulator?

Answer: The Grenfell Tower fire

54

Your cables pass through a wall that already has fire-stopping. You have to remove some to fit them. What must happen?

Answer: The fire-stopping is put back properly with suitable products

55

Which of these is a fire-separating element in a building?

Answer: A compartment wall or compartment floor

56

What does fire-stopping delay, as well as the spread of fire?

Answer: The spread of smoke

57

Which kinds of work does HSE count as hot work that can start a fire?

Answer: Any work that makes heat, sparks or flame, such as using a blow torch

58

Before soldering with a blow torch, what should you do with nearby combustible materials?

Answer: Clear them away from the area

59

What should you have close by when doing hot work?

Answer: A suitable fire extinguisher

60

On larger projects, what system can help control the fire risk from hot work?

Answer: A permit to work system

61

In a 2026 HSE case, a roof caught fire during a heat pump job. What did sparks from welding ignite?

Answer: Uncovered rigid foam insulation

62

Why does HSE say LPG needs strict precautions on site?

Answer: Leaks, especially in confined areas, have caused serious fires and explosions

63

Where does HSE say LPG and other flammable materials should be stored, where possible?

Answer: Outside the building under construction

64

If flammable liquids or gases have to be kept inside a building, what does HSE advise?

Answer: Keep only small amounts in the work area until they are needed

65

What must electrical equipment used in a flammable atmosphere be?

Answer: Suitable for that type and extent of flammable atmosphere

66

How should welding gas cylinders be stored?

Answer: Upright, chained to a rack or trolley, preferably outdoors

67

Where should flashback arrestors be fitted on oxy-fuel equipment?

Answer: Near the regulator on both the fuel and oxygen supplies

68

How should you test oxy-fuel hoses and connections for leaks?

Answer: With leak-testing fluid, never a flame

69

What must never be put on oxygen fittings?

Answer: Grease, oil or other lubricants

70

At the end of the working day, what should you do with oxy-fuel equipment?

Answer: Shut off cylinder valves, purge the hoses and close the blowpipe valves

71

An acetylene cylinder involved in a flashback starts to feel warm or vibrate. What should you do?

Answer: Evacuate the area and call the Fire and Rescue Service

72

How large an area does HSE say to evacuate around a heated acetylene cylinder?

Answer: 200 metres

73

Why can acetylene be dangerous even without air or oxygen present?

Answer: It can decompose explosively on its own

74

What colour are compressed acetylene cylinders?

Answer: Maroon

75

Where possible, which fuel gas does HSE suggest using instead of acetylene?

Answer: Propane

76

What should happen to faulty hoses, gauges or regulators?

Answer: Withdraw them and label them clearly as not for use

77

Why must you never weld or heat a container that may hold flammable residues?

Answer: The residues can ignite or explode

78

Why is a flammable gas release more dangerous in an enclosed space than outdoors?

Answer: An ignition is more likely to cause an explosion than a fire

79

Why does HSE warn about the out-of-hours risk in rooms with flammable gas plant?

Answer: Ventilation may be shut down, letting leaks build up

80

What does Approved Document B say ductwork must not do in a fire?

Answer: Help to transfer fire and smoke through the building

81

Air handling ducts pass through a fire-separating wall. What must be maintained?

Answer: The fire performance of the wall

82

Which of these is one of the four methods Approved Document B gives for ducts through fire-separating elements?

Answer: Thermally activated fire dampers

83

Why should thermally activated fire dampers not be used in kitchen extract ductwork?

Answer: Grease build-up can stop the dampers working properly

84

Why should thermally activated dampers not be used for extract ducts through protected escape routes?

Answer: Large amounts of smoke can pass before the heat triggers them

85

What should operate a fire and smoke damper where ductwork enters a protected escape route?

Answer: A smoke detector or suitable fire detection system

86

Can ventilation ducts serving a protected stairway also serve other areas?

Answer: No, each protected stairway needs its own ventilation system

87

Where a duct passes through a stair enclosure, what should the joint between them have?

Answer: Fire-stopping

88

Where should welding gas hoses be kept during work?

Answer: Away from risks of damage, such as traffic routes

89

Why should charged hoses not be left for long periods in poorly ventilated areas?

Answer: Leaking gas could build up to a dangerous level

90

Before hot work near a vehicle or panel, why should you check cavities for plastic foam?

Answer: Foam ignites easily, so remove it or use a heat shield