1

Which power tools does HSE recommend for construction sites?

Answer: Cordless tools, or tools on a 110V centre-tapped-to-earth supply

2

On a 110V centre-tapped-to-earth supply, what is the maximum voltage to earth?

Answer: 55V

3

Can tools, plugs and cables made for DIY and home use be used on site?

Answer: No — they are not suitable for site conditions

4

You notice the cable on your power tool is damaged. What should you do?

Answer: Stop using it and take it out of service — don't make a makeshift repair

5

What does an RCD (residual current device) do?

Answer: Detects some, but not all, electrical faults and quickly switches off the supply

6

What rating of RCD gives useful protection against electric shock?

Answer: No more than 30 mA

7

If a circuit is protected by an RCD, can you work on it while it is live?

Answer: No — an RCD can't protect you from every shock, so isolate the circuit first

8

How often should 230V equipment used on site have a visual check for damage?

Answer: Every shift

9

When is work on or near a live electrical conductor allowed?

Answer: Only when it is unreasonable for it to be dead, reasonable to work live, and suitable precautions are taken

10

Refurbishment work could damage the building's existing electrics. What should happen first?

Answer: The relevant parts should be isolated, following safe isolation procedures

11

Overhead power lines cross your work area. How should you treat them?

Answer: As live, unless their owner has proved otherwise

12

Can you be hurt by an overhead power line without touching it?

Answer: Yes — getting close to live conductors can cause a "flashover"

13

Where work under live overhead lines can't be avoided, what should be provided?

Answer: Barriers, goal posts and warning notices

14

What are the two best ways to remove the danger of overhead lines from a work area?

Answer: Divert the lines clear of the area, or have them made dead while the work goes on

15

The jib of your machine has touched an overhead power line. What should you do first?

Answer: Stay in the cab and call the network operator immediately

16

If you have to leave a vehicle that is in contact with an overhead line, how should you get out?

Answer: Jump well clear, so you never touch the vehicle and the ground at the same time

17

A machine touched an overhead line and the power seems to have gone off. Is it safe to approach?

Answer: No — the line may be switched back on automatically, without warning

18

Why are underground electricity cables particularly dangerous when digging?

Answer: They often look like pipes, and you can't tell by looking whether they are live

19

There are no plans showing buried services for an emergency dig. How should the work be done?

Answer: As though there are live buried services in the area

20

How accurate are utility plans of underground services?

Answer: They only give an indication of where services are and how many there are

21

How often should a cable locator be used during excavation work?

Answer: Frequently and repeatedly throughout the work

22

How should you dig near a buried cable that has been located?

Answer: By hand, alongside the cable rather than directly above it

23

What kind of tools should be used when hand digging near electric cables?

Answer: Insulated tools

24

You got a small electric shock last week and weren't hurt. What does HSE say about this?

Answer: Nobody is immune — being unhurt was just luck

25

Which conditions does HSE say increase the risk of electric shock?

Answer: Damp and lots of metalwork

26

You come across an electrical installation on site that looks unsafe. What does HSE say to do?

Answer: Warn people away, switch off if safe, call a competent person

27

How should an RCD be checked regularly?

Answer: Press its test button; take it out of use if faulty

28

An RCD is plugged into one socket. Which equipment does it protect?

Answer: Only what is plugged into that socket

29

Equipment has been isolated so that someone can work on it. What does HSE say should happen?

Answer: Lock each isolation device, keep the keys with the person doing the work, and post warning notices

30

Before work starts on conductors that have been isolated, what must be done?

Answer: Prove them dead with suitable test equipment

31

You see someone on site doing electrical work unsafely. What does HSE suggest?

Answer: Ask them to stop, tell a manager, and tell HSE if you still think it is unsafe

32

Overhead wires on wooden poles cross your site. What should you assume?

Answer: They could be power lines — don't mistake them for telephone wires

33

Can damp or dirty wood or plastic conduct electricity?

Answer: Yes — enough to cause fatal shocks

34

Which of these is at particularly high risk of touching overhead power lines?

Answer: Tall kit such as tippers, MEWPs, cranes and scaffold poles

35

Plant has to cross under live overhead lines. How should the crossing passageway be set out?

Answer: As narrow as safe, crossing at right angles

36

Who should you get the safe clearance distance for working under overhead lines from?

Answer: The owner of the line

37

At what voltage can contact with an overhead line be lethal?

Answer: As low as 230 volts

38

A tree near an overhead power line on site needs cutting back. What does HSE say?

Answer: Don't cut trees near overhead lines yourself — raise it with the line's owner

39

An excavator touches an overhead line and becomes live. Who is at risk?

Answer: Anyone near the plant

40

Plant on site touches an overhead power line, but nobody is hurt. Is this reportable under RIDDOR?

Answer: Yes — contact with overhead power lines by plant or equipment is reportable

41

HSE says an electric current can flow through the body from about what voltage?

Answer: 50 volts

42

Which of these is a direct effect of an electric shock on the body?

Answer: The heart can stop beating properly

43

Why can a person who gets an electric shock be unable to let go of the live part?

Answer: Muscle spasms stop them letting go

44

How does an electric current cause burns inside the body?

Answer: It heats the tissue along its path

45

You are working on a stepladder and get a small electric shock. What extra danger does HSE warn about?

Answer: You could fall from height

46

Which conditions make an electric shock more likely to injure you?

Answer: Damp conditions and nearby metalwork

47

Where could a single small torch battery cause a dangerous spark?

Answer: Near fuel tanks or in a paint spray booth

48

What is the highest rating an RCD should have to give useful protection against electric shock?

Answer: 30 mA

49

How should you check that an RCD is working?

Answer: Press its test button regularly

50

An RCD is fitted to the circuit you need to work on. What should you still do?

Answer: Isolate the circuit before you start

51

According to HSE, how often should a user check 230V mains equipment on a construction site?

Answer: Daily or every shift

52

How often does HSE suggest a combined inspection and test for 110V equipment on a construction site?

Answer: Before first use on site, then every 3 months

53

Which of these is a sign that a power tool cable is not safe to use?

Answer: It has been repaired with insulating tape

54

You see burn marks and staining on a plug. What does this suggest?

Answer: The plug has been overheating

55

Are DIY or household extension leads suitable for use on a construction site?

Answer: No, they are not made for site conditions

56

Who should repair a damaged power tool on site?

Answer: A qualified electrician or the supplier

57

Under the Electricity at Work Regulations, who may do electrical work where technical knowledge is needed to prevent danger?

Answer: Someone with the right knowledge or experience, or suitably supervised

58

You are not sure how to check that a circuit is dead. What does HSE advise?

Answer: Ask a competent person to check it for you

59

What must happen before work on an electrical system starts, according to HSE?

Answer: The supply is made dead and proved dead

60

What should the isolation method do, as well as cutting off the supply?

Answer: Stop the circuit being switched back on by accident or on purpose

61

What is a good way to make sure an isolating switch stays off?

Answer: Lock it off and keep the only key yourself

62

Why is taking out a fuse not enough on its own to isolate a circuit?

Answer: Someone could put another fuse in its place

63

Before you use a voltage tester to check a circuit is dead, what must you be sure of?

Answer: The tester and the way you use it work reliably

64

What does HSE warn about some cable detectors?

Answer: They may not find a wire carrying a small current

65

An electrician was badly shocked because a supply had not been properly isolated. Under which law was the company prosecuted, as well as the Health and Safety at Work Act?

Answer: The Electricity at Work Regulations 1989

66

What does HSE say about working on live electrical equipment?

Answer: It is never absolutely safe

67

Under regulation 14 of the Electricity at Work Regulations, live working is only allowed when which of these is true?

Answer: It is unreasonable for the conductor to be dead, it is reasonable to work live, and suitable precautions are taken

68

Your supervisor asks you to work live on a circuit just to save time. What should happen?

Answer: Work dead, because saving time is not a reason to work live

69

Which tools does HSE recommend for construction sites to reduce the risk of electric shock?

Answer: Cordless tools, or tools on a 110V centre-tapped-to-earth supply

70

How often does HSE say RCDs on site should be checked?

Answer: Daily

71

HSE says which type of power tool is the safest on a construction site?

Answer: Battery-operated tools

72

When can standard 13A socket outlets be used on a construction site?

Answer: Only if they are a suitable type, protected from the weather and protected by an RCD

73

Can you use twin and earth cable to make an extension lead?

Answer: No, it is not suitable for extension leads

74

A site cable crosses a roadway used by vehicles. How should it be laid?

Answer: In a duct at least 0.5 m below the surface, with a marker at each end

75

If a cable has to be suspended across a site road, what clearance does HSE give underneath it?

Answer: 5.8 m or more

76

Why should you never run a generator in an enclosed space?

Answer: It can produce dangerous carbon monoxide

77

What is special about double-insulated (Class II) equipment?

Answer: It has high-integrity insulation and does not need an earth connection

78

What is the danger if the earth connection on earthed (Class I) equipment is lost?

Answer: The metal outside of the equipment could become live

79

What can high-power laser light do to your eyes?

Answer: Cause serious damage, including blindness

80

Who should carry out maintenance or repairs that give access to a laser?

Answer: Only trained and authorised people

81

How does an employer decide if workers need protective eyewear for laser work?

Answer: From their risk assessment

82

On a building site, what colour are 110V leads, plugs and sockets usually?

Answer: Yellow

83

Why must small offcuts of optical fibre be put in a proper waste container?

Answer: The tiny glass pieces can get into your skin or eyes

84

Why should you never look into the end of an optical fibre?

Answer: The light in it can be strong enough to harm your eyes

85

Three electricians are working on circuits from the same switched-off board. How should the isolator be kept off?

Answer: A multi-lock hasp, with each worker fitting their own padlock

86

When you prove a circuit is dead, what do you check first?

Answer: That your voltage detector works, using a proving unit or known live source

87

Is a non-contact "voltage stick" enough on its own to prove a circuit is dead?

Answer: No, prove it dead with a proper two-pole tester or test lamp

88

What electrical protection does HSE say electric welding equipment needs?

Answer: Fuse (overload) protection and a suitably rated RCD

89

In stick (MMA) welding, where should the electrode holder be rested when not in use?

Answer: In an insulated box or on a hook

90

How should the workpiece be earthed for arc welding?

Answer: With a robust flexible cable and clamp

91

In MIG welding, what should the electrode wire be kept from touching?

Answer: Earthed metalwork